Flasher Hub-4
Compact High-Volume Production Programming
Compact gang-programming control unit for up to 4 Flasher Compact channels
Scalable to 24 channels using SEGGER USB Hubs for mass production
Supports different devices or firmware per channel for flexible production setups
1. Key Features
2. How Flasher Hub-4 Works
3. Flasher Compact - The space-efficient programmer
4. Flasher SDK
5. Cross-Platform Software
6. Technical Specifications

Key features

Stand-Alone Operation
SEGGER's Flasher Hub-4/ Flasher Compact system is set up once per channel using SEGGER's Flasher software, tailored to the flash chip type. The Flasher Hub-4 can operate independently via TELNET, without the need for a desktop PC.

High Scalability
Start small and expand. Flasher Hub-4 allows parallel programming of up to 24 programming units, each serving as an individual channel. It can be connected to up to 24 Flasher Compacts using the SEGGER USB Hub-7. Each Flasher Compact retains full independence for mixed-target environments.

Complete System Configurability
Flasher Hub-4 can be controlled and configured via its built-in web server. Thanks to the intuitive user interface, operators can view all necessary status information at a glance, ensuring smooth production flow.
How Flasher Hub-4 Works
Flasher Hub-4 facilitates efficient, parallel programming of multiple devices through its integration with Flasher Compact units. Designed for high-speed gang programming, the Flasher Hub-4 offers two distinct operating modes: Direct Mode and Flex Mode.

Direct Mode (Standard Setup)
In Direct Mode, SEGGER's Flasher Hub-4 manages up to four Flasher Compact modules independently. Each module operates as a separate programming channel, directly connected to the Flasher Hub-4 via USB. This mode is ideal for setups requiring straightforward, individual control of up to four devices simultaneously without the need for additional USB hubs.

Flex Mode (Expanded Setup)
Flex Mode expands the capabilities of the Flasher Hub-4 by enabling the connection of up to 24 Flasher Compact modules using external USB hubs. This configuration provides scalable programming solutions for high-volume production environments where flexibility and efficiency are paramount. In Flex Mode, each Flasher Compact module can be dynamically assigned to any available programming channel, maximizing throughput and adaptability.
Please note: For optimal operation, SEGGER's recommend using the SEGGER USB Hub-13. SEGGER only provides technical support for setups with SEGGER USB Hubs.
SEGGER's Flasher Hub-4 is simple to set up and can be operated via TELNET or RS232, utilizing the built-in ASCII command interface, which is optimized for automation. It also includes a user-friendly web interface that allows for easy manual operation, providing intuitive control and monitoring of all connected devices.
Additionally, SEGGER's Flasher Hub-4 supports programming of unique data that differs between otherwise identical units. This includes serial numbers, Ethernet hardware addresses (MAC), digital signatures, and license keys that enable or disable product features. These unique data pieces can be applied to the firmware during programming, ensuring that each device is customized according to its specific requirements.
Built-In Web Server
SEGGER's built-in web server of the Flasher Hub-4 (using emWeb) simplifies configuration and setup of the programming system. In addition, it offers options to check status information remotely and to manage firmware images.
Remote Monitoring
SEGGER's built-in web server is designed to present important device and current operation data for a quick overview and, additionally, to check the status of the programmer, providing information about:
- Installed firmware version
- Hardware version
- Power consumption
- IP configuration
- Network load
- Current operation and status
- Programming interface in use
This may be important for fast troubleshooting through code verification, for instance, as it is when executing a cyclic redundancy check (CRC) that helps to detect errors during data transmission or storage.

Configuration
If needed, SEGGER's built-in web server programmer settings can be checked and adjusted. These could, for example, be parameters like:
- Subnet mask
- Gateway

File Management
SEGGER's built-in web server enables file management for all connected modules. This includes
- Firmware images
- Setup files

Built-in FTP Server
SEGGER's Flasher Hub-4 also includes a built-in FTP server to upload firmware and configuration or download log files.
Remote File Update
Using the emFTP server enables easy upload of configuration files and firmware images. By connecting to the emFTP server using an FTP client of choice, files can be transferred between client and Flasher.
Having access to the Flasher configuration via FTP enables configuration of multiple Flasher from a central production control server. This interface also can be used to make the production line part of a CI/CD system to push stable releases into the current production.

Log File
Analyzing the reliability of the production line is an important task, when it comes to increasing the production speed and volume. This purpose is supported by the built-in FTP server, which lets users check the history of past programming cycles via log file download. Each entry provides the following information:
- Result (success/failure)
- Duration
- Serial number (if programmed)
For failed programming cycles, the log file provides additional information for quick troubleshooting (e.g. failed to open Flasher config file).
Flasher Compact - The Space-Efficient Programmer

SEGGER's Flasher Compact is high-speed, stand-alone in-system programmer. When connected to a Flasher Hub-4, each unit acts as an individual channel for parallel, high-volume programming. It supports a wide range of devices and allows unique data, such as serial numbers or license keys, to be programmed for each target.
Flasher SDK
If a new device is not yet natively supported by a Flasher, users can add support themselves using the Flasher Software Development Kit. This makes the Flasher SDK ideal for integrating proprietary hardware or new components into production workflows.

Programming FPGAs and CPLDs
Production departments faced with the task of programming FPGAs or CPLDs do not require the Flasher SDK, as Flasher programmers can program FPGAs and CPLDs using the Flasher BitStreamer.

Cross-Platform Software
A multi-platform solution, Flasher Hub-4 comes with SEGGER's Flasher Software and Documentation Package for Windows, Linux, and macOS. It provides the tools and resources necessary for configuring, managing, and using the Flasher Pro effectively. It also includes flash loaders for all supported devices, including a wide range of target microcontrollers.
The software package can be downloaded free of charge, and it includes future software and firmware updates, as well as all new flash loaders for target devices added in the future.
Customer Support
Every Flasher comes with one year of Initial Coverage and Warranty, providing hardware warranty and support. At the time of purchase, Coverage and Warranty can be extended to a total period of 3 to 5 years.
To extend coverage beyond the initial period, Extended Coverage and Warranty can be purchased.
Please note: Support is available for registered products only.
Organizations with a larger number of SEGGER hardware products may benefit from Company Support. This allows engineers to receive technical assistance regardless of the coverage status of their individual devices.
Product Images



Flasher Hub-4 front
Flasher Hub-4 Host Connector
Flasher Hub-4 Target Connector
Technical Specifications
| Specifications | |
| Power supply | 8-30 VDC, reverse polarity protected, max. 30 W [1] |
| Power consumption | Max. 11.5 W [1] |
| USB Flasher interface | 4 x USB-C 2.0 High Speed (Downstream) |
| Host interfaces | USB-C 2.0 High Speed (Upstream), USB Type-A (Downstream), Ethernet, RS232 9-pin |
| Operating temperature | +5 °C ... +60 °C |
| Storage temperature | -20 °C ... +65 °C |
| Relative humidity (non-condensing) | < 90 % rH |
| Size (without cables) | 125 mm x 78 mm x 25 mm |
| Weight (without cables) | 135 g |
[1] Depends on current consumption of connected downstream devices. For maximum load, the input supply must provide 12 VDC or more.
Package Content



Flasher Hub-4
Power Connector
USB-C Cable