• Semtech SX1262 Engine
  • Excellent blocking immunity
  • Low receive current
  • Detect channel motion to set power-saving CAD reception mode on
  • High sensitivity
  • Control easily by AT commands
  • Built-in antenna
  • AES128 Data encryption

Description

The RYLR907 transceiver module feature the Lora long range modem that provides ultra-long range spread spectrum communication and high interference immunity whilst minimising current consumption.

Specification

ItemMin.TypicalMax.UnitCondition
VDD Power Supply23.33.6VVDD
RF Output Power Range-422dBm
Filter insertion loss123dB
RF Sensitivity-148dBm
RF Input Level10dBm
Frequency Range820868/915960MHz
Frequency Accuracy±2ppm
Communication RangeKMDepend on RF parameter
Transmit Mode Current140mARFOP = +22dBm
Receive Mode Current10.4mAAT+MODE=0, AT+RXBOOST=1
9.9mAAT+MODE=0, AT+RXBOOST=0
CAD Mode Receive Current2.3mAAT+MODE=2
Sleep Current0.5uAAT+MODE=1
Digital Input Level High0.7*VDDVDDVVIH
Digital Input Level Low00.3*VDDVVIL
Digital Output Level High0.9VDDVVOH
Digital Output Level Low0.1VVOL
Cycling (erase / write)
EEPROM data memory
300KCycles
Weight7g