Conductivity electrodes for laboratory and field measurements.

FEATURES:

  • Field and laboratory models
  • Wide conductivity ranges offered
  • Applications include general solution measurement, ultrapure water, organic media, cosmetics, industrial, and many more…

Conductivity Electrodes Product Description

In research and development, manufacturing, and quality control, SI Analytics ScienceLine conductivity electrodes have long since become standard for the most demanding measuring tasks. Each conductivity electrode has an individual serial number making documentation easier and more traceable. The ScienceLine conductivity electrodes from SI Analytics not only have high measurement accuracy, stability, and long service life, but are highly adaptable to your measuring requirements.

Conductivity electrodes measure the composite ion concentration of a solution.  Conductivity electrode measurement applications range from monitoring process water in industrial plants to measuring ultrapure water in quality control labs.  Consequently, a wide range of conductivity electrodes have been designed to meet these different applications.  The flow-through conductivity electrodes, LF 213T and LF 313T, with a cell constant of 0.1 and 0.01 cm-1 are ideal for the measurement and control of pure water.  With an extremely wide measuring range, an abrasion proof graphite housing, and an automatic resistance compensation feature, the LF 413T combined 4-pole conductivity electrode is ideal for most applications, has a long life while providing you with accurate measurements even with a dirty conductivity cell.  The glass platinum conductivity electrode LF 713T (4-pole) and LF 913T (5-pole) allow the determination of conductivity in organic media.  The models LF 1100(T)+, LF 4100+ and LF 5100(T)+ offer the possibility of connecting these conductivity electrodes to diverse instrument types via the SMEK plug head and appropriate cable.

Conductivity cell measurements
Conductivity is a parameter used to measure the ionic concentration and activity of a solution.  The more salt, acid or alkali in a solution, the greater its conductivity.  The unit of conductivity is S/m, often also S/cm.  The scale for aqueous solutions begins with pure water at a conductivity of 0.05 uS/cm (77 °F /25 °C).  Naturally occurring waters such as drinking water or surface water have a conductivity in the range 100 – 1000 uS/cm.  At the upper end of the chart some acids and alkalines can be found.

Conductivity cell measurements are used for a wide range of applications such as the production of ultrapure water or determining the salinity of sea water.

Conductivity is measured by using a conductivity cell to make a measurement of the electrical resistance. The simplest kind of measuring cell used consists of two similar electrodes. An alternating voltage applied to one of the conductivity electrodes causes the ions in the solution to migrate towards the electrodes. The more ions in the solution, the greater the current which flows between the conductivity electrodes. The conductivity meter measures the current produced by the conductivity cell and uses Ohm’s law to calculate first the conductance of the solution and then – by taking the cell data into account – the conductivity.

Conductivity Electrodes Specifications

SCIENCELINE CONDUCTIVITY ELECTRODES WITH FIXED CABLES

ScienceLine LF 213T Trace Conductivity Electrode (PN# 285106150)
Trace conductivity electrode with integrated stainless steel flow through cell, 4.9 ft (1.5 m) cable with 8 pole plug, stainless steel sensor, cell constant 0.01 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.79 inch (20 mm) Ø, 32 to 212 °F (0 to 100 °C)

ScienceLine LF 213T-ID Trace Conductivity Electrode (PN# 285106160)
Trace conductivity electrode with integrated stainless steel flow through cell, sensor ID recognition, 4.9 ft (1.5 m) cable with 8 pole plug, stainless steel sensor, cell constant 0.01 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.79 inch (20 mm) Ø, 32 to 212 °F (0 to 100 °C)

ScienceLine LF 313T Ultrapure Water Conductivity Electrode (PN# 285414360)
Ultrapure water conductivity electrode with glass flow through cell, stainless steel shaft, 4.9 ft (1.5 m) m cable with 8 pole plug, stainless steel sensor, cell constant 0.1 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 313T-ID Ultrapure Water Conductivity Electrode (PN# 285130300)
Ultrapure water conductivity electrode with glass flow through cell, sensor ID recognition, stainless steel shaft, 4.9 ft (1.5 m) m cable with 8 pole plug, stainless steel sensor, cell constant 0.1 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 313T NFTC Ultrapure Water Conductivity Electrode (PN# 285414351)
Ultrapure water conductivity electrode without flow through cell, stainless steel shaft, 4.9 ft (1.5 m) m cable with 8 pole plug, stainless steel sensor, cell constant 0.1 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 32 to 212 °F (0 to 100 °C)

ScienceLine LF 413T 4-pole Conductivity Electrode (PN# 285106172)
4 pole conductivity electrode, plastic shaft, 4.9 ft (1.5 m) cable with 8 pole plug, sensor material graphite, cell constant 0.475 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.6 inch (15.3 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 413T-ID 4-pole Conductivity Electrode (PN# 285130310)
4 pole conductivity electrode, plastic shaft, 4.9 ft (1.5 m) cable with 8 pole plug, sensor ID recognition, sensor material graphite, cell constant 0.475 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.6 inch (15.3 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 413T-3 4-pole Conductivity Electrode (PN# 285106148)
4 pole conductivity electrode, plastic shaft, 9.8 ft (3 m) cable with 8 pole plug, sensor material graphite, cell constant 0.475 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.6 inch (15.3 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 513T 2-pole Conductivity Electrode (PN# 285106037)
2 pole conductivity electrode, plastic shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor 2 platinum rings, cell constant 1.0 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 613T 4-pole Conductivity Electrode (PN# 285106131)
4 pole conductivity electrode, plastic shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor 4 platinum rings, cell constant 1.0 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 713T 4-pole Conductivity Electrode (PN# 285106189)
4 pole conductivity electrode, glass shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor 4 platinum rings, cell constant 1.0 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LF 713T-250 4-pole Conductivity Electrode (PN# 285106190)
4 pole conductivity electrode, glass shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor 4 platinum rings, cell constant 1.0 cm-1, temp. sensor NTC 30 kOhm, length 9.8 inch (250 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LF 813T 5-pole Conductivity Electrode (PN# 285106250)
5 pole conductivity electrode, plastic shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor 5 platinum rings, cell constant 0.650 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 913T 5-pole Conductivity Electrode (PN# 285106260)
5 pole conductivity electrode, glass shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor 5 platinum rings, cell constant 0.650 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LF 913T-ID 5-pole Conductivity Electrode (PN# 285106270)
5 pole conductivity electrode, glass shaft, 3.3 ft (1 m) cable with 8 pole plug, sensor ID recognition, sensor 5 platinum rings, cell constant 0.650 cm-1, temp. sensor NTC 30 kOhm, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LFOx 1400 Combined Dissolved Oxygen and Conductivity Electrode (PN# 285104630)
Combination galvanic oxygen and 4-pole conductivity electrode, plastic shaft, 9.8 ft (3 m) cable with 8 pole plug, conductivity sensor material graphite, cell constant 0.475 cm-1, temp. sensor NTC 30 kOhm, length 5.7 inch (145 mm), 0.6 inch (15.3 mm) Ø, 32 to 122 °F (0 to 50 °C)

ScienceLine LFOx 1400 ID Combined Dissolved Oxygen and Conductivity Electrode (PN# 285130330)
Combination galvanic oxygen and 4-pole conductivity electrode, plastic shaft, 9.8 ft (3 m) cable with 8 pole plug, sensor ID recognition, conductivity sensor material graphite, cell constant 0.475 cm-1, temp. sensor NTC 30 kOhm, length 5.7 inch (145 mm), 0.6 inch (15.3 mm) Ø, 32 to 122 °F (0 to 50 °C)

SCIENCELINE CONDUCTIVITY ELECTRODES WITH PLUG HEADS

ScienceLine LF 1100+ 2-pole Conductivity Electrode (PN# 1069976)
2 pole conductivity electrode, glass shaft, SMEK plug head, sensor 2 platinum plates, cell constant 1.0 cm-1, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LF 1100T+ 2-pole Conductivity Electrode (PN# 1069977)
2 pole conductivity electrode, glass shaft, SMEK plug head, sensor 2 platinum plates, cell constant 1.0 cm-1, temp. sensor Pt 1000, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LF 4100+ 2-pole Conductivity Electrode (PN# 1069978)
2 pole conductivity electrode with flow through cell, glass shaft, SMEK plug head, sensor 2 platinum plates, cell constant 1.0 cm-1, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, -22 to 275 °F (-30 to 135 °C)

ScienceLine LF 5100+ 2-pole Conductivity Electrode (PN# 1069979)
2 pole conductivity electrode, plastic shaft, SMEK plug head, sensor 2 platinum rings, cell constant 1.0 cm-1, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

ScienceLine LF 5100T+ 2-pole Conductivity Electrode (PN# 1069990)
2 pole conductivity electrode, plastic shaft, SMEK plug head, sensor 2 platinum rings, cell constant 1.0 cm-1, temp. sensor Pt 1000, length 4.7 inch (120 mm), 0.47 inch (12 mm) Ø, 23 to 176 °F (-5 to 80 °C)

SCIENCELINE CONDUCTIVITY ELECTRODES CABLES

LS 1 D8 Conductivity Electrode Cable (PN# 1066726)
Electrode plug (for SMEK-plug head), 3.3 ft (1 m) cable, 8-pole plug

SCIENCELINE CONDUCTIVITY ELECTRODE STANDARDS

LF 990 Conductivity Electrode Calibration Solution (PN# 285126503)
3×6 20 mL ampoules, test solution potassium chloride 0.001 mol/l (147 µS/cm)

LF 991 Conductivity Electrode Calibration Solution (PN# 285126511)
3×6 20 mL ampoules, test solution potassium chloride 0.01 mol/l (1.41 mS/cm)

LF 992 Conductivity Electrode Calibration Solution (PN# 285126528)
3×6 20 mL ampoules, test solution potassium chloride 0.1 mol/l (12.9 mS/cm)

LF 995 Conductivity Electrode Calibration Solution Kit (PN# 285126293)
Includes 6 ampoules with 20 ml each potassium chloride 0.01 mol/l (1.41 mS/cm), 6 ampoules with 20 ml each potassium chloride 0.1 mol/l (12.9 mS/cm), and 6 ampoules with 20 ml each potassium chloride 1 mol/l (112 mS/cm)

LF CSKC13 Conductivity Electrode Calibration Solution (PN# 285126530)
250 ml bottle conductivity test solution 1.3 uS/cm, shelf life: sealed 3 months, opened 6 hours

LF CSKC5 Conductivity Electrode Calibration Solution (PN# 285126540)
500 ml bottle conductivity test solution 5 uS/cm, shelf life: sealed 6 months, opened up to the maximum shelf life of 6 months

RELATED PRODUCTS

TetraCon® 325-3 Handheld Conductivity Meter Probe (PN# 301970)
Includes 9.8 ft (3 m) cable.

2CA102 Cond 3110 Set Handheld Conductivity Meter Set
Includes meter, TetraCon 325-3 probe, case & accessories.

Lab 960 Benchtop Conductivity Meter

ProLab 4000 Multiparameter Benchtop Meter

EC30A Conductivity Tester
Includes meter and conductivity cell, batteries, and instruction manual.

EC300ACC Field Conductivity Meter Kit
Includes field conductivity meter, cable with attached conductivity/temperature probe, and hard sided case.

EC500 Pocket pH/Conductivity Tester
Includes electrode, protective sensor cap, sample cup with cap, four 1.5V SR44W batteries, and a 48 inch (1.2m) neckstrap.

EC510 Pocket pH/Conductivity Tester Kit
Includes an EC500 portable conductivity meter with sensor, 84uS, 1413uS, 12880uS calibration standards, pH buffer pouches (1 each of 4, 7, 10pH plus rinse solution), weighted base, protective sensor cap, 3 sample cups, four 1.5V SR44W batteries, carrying case, and a 48 inch (1.2m) neckstrap.

WQ-Cond Conductivity Sensor
4-20mA output.  Includes 25 ft of cable.

WQ Water Quality Sensors