Flanged electromagnetic flow meters for full-pipe municipal or industrial water and wastewater applications.

FEATURES:

  • Simple and economical as a mechanical meter
  • No moving parts for low maintenance & long life
  • Minimal straight pipe required
  • Pulse output for loggers, PLC’s, or telemetry

Electromagnetic Flow Meters Product Description

The WMX101-Series flanged electromagnetic flow meters are the perfect replacement for your old 4 to 10 inch industrial mechanical turbine or propeller flow meters. Because the electromagnetic flow meters have no moving parts and have electrodes designed to discourage fouling, the flow meter performs well and requires much less frequent maintenance in applications where debris would impede propeller meters. These electromagnetic flow meters do not have rotors which stop turning or bearings which wear out. WMX101-Series flanged electromagnetic flow meters are also designed to work with minimal straight pipe run requirements, which is great when you have very little space between the meter and an elbow.

The WMX Series flanged electromagnetic flow meters’ electronics are housed in a rugged NEMA 4X aluminum enclosure with a 2-line LCD that clearly displays the flow rate and totalizer. The industrial electromagnetic flow meters’ display housing is fitted with tamper-evident features. An optional IP68 (NEMA 6P) rated housing is available for applications where the electromagnetic flow meter may be under water up to a depth of 9.8 ft (3 m) for prolonged periods of time.

The WMX101 electromagnetic flow meters are externally powered with 8-32 Vdc at 30 mA max (see NOTE in Specifications). A tamper-sealed shielded power/pulse output cable is included with the electromagnetic flow meter. Two Lithium 3.6V “AA” batteries provide auxiliary power during power failures, allowing the electromagnetic flow meter to continue recording flow rate and total without interruption for the duration of the outage. Where external power loss is infrequent, the electromagnetic flow meter battery life can exceed 10 years. The electromagnetic flow meter’s 20-foot power cable also provides a pulse output for use with a variety of devices such as a FT420 4-20mA converter and remote display, PLC, telemetry system, or data logger. High frequency pulse rate (required for use with 4-20 mA converters) is standard with the electromagnetic flow meters; additional pulse rates are optional. A pulse-to-analog converter can be added if a 4-20 mA signal is needed from the electromagnetic flow meter.

The WMX104 electromagnetic flow meters are battery-operated meters for use when pulse output is not required or line power is not readily available. Two Lithium 3.6V “D” batteries provide power to the electromagnetic flow meter and are replaceable with an approximate 1-year life under continuous use, or more depending on the duty cycle. An optional input/output cable can be installed post-factory on the electromagnetic flow meter if a pulse output is needed.

Rate and total indication are standard on both electromagnetic flow meter models. Electromagnetic flow meters are customer-selected and factory-set. The electromagnetic flow meter’s display units will be set to GPM for flow rate and US Gallons for total flow if no units are selected at the time of purchase. These units cannot be changed on the electromagnetic flow meters in the field. If you would like alternate units to display the electromagnetic flow meters support the following options: Rate: MGD, Liters/minute, Liter/second, CFM, CMH, Mega Liter/day; Total: Gallons, Gallons x 1000, Liter, Liter x 1000, Mega Liter, CU Feet, CU Feet x 1000, CU Meters, CU Meter x 1000.

Electromagnetic Flowmeters Applications

  • Filtration systems
  • Pump stations
  • Municipal water/wastewater
  • Industrial water/wastewater
  • Cooling tower water treatment
  • Well usage reporting

NOTE: In chemical injection applications, the chemical injection point must be placed downstream of the electromagnetic flow meter OR far enough upstream for complete mixing to occur before the fluid reaches the flow meter.

Flow Sampling System Specifications

Pipe Sizes: 4, 6, 8, or 10 inch
Flow Range:
     4″    12-1000 GPM (0.75-63 L/s)
     6″    32-2400 GPM (2-151.4 L/s)
     8″    60-4400 GPM (3.8-277.6 L/s)
     10″  95-7000 GPM (6-441.6 L/s)
Accuracy:
     +1% of reading from 10% to 100% of max flow
     +2% of reading from cutoff to 10% of max flow
Fittings: AWWA 150 lb. drilling
Pressure: 150 PSI (10.3 bar) working pressure
Operating Temperature: 10° to 130° F (-12° to 55° C)
Storage Temperature: -40° to 158° F (-40° to 70° C)
Materials:
     Body: Welded steel, epoxy-coated
     Liner: Dual durometer rubber
     Electronics Housing: Die cast aluminum, powder coated
     Electrodes: 316 stainless steel
Rate Display: 5-digits in units of GPM (standard), MGD, Liters/minute, Liter/second, CFM, CMH, Mega Liter/day
Totalizer Display: 8-digits in units of Gallons, Gallons x 1000, Liter, Liter x 1000, Mega Liter, CU Feet, CU Feet x 1000, CU Meters, CU Meter x 1000
Power:
     101*: 8-32 VDC @ 30 mA, with auxiliary battery for continuous operation during power failures
     104: 2 Lithium 3.6V “D” batteries, replaceable, 1 year life under continuous use
Output Signal:
     101: Current sinking pulse, opto-isolated, 30 Vdc at 10 mA max
     104: Pulse output available only with addition of DC30 output cable
Pulse Rates: High Frequency (default); 10 units/pulse; 100 units/pulse; 1000 units/pulse
High Frequency Pulse:
     4″    16.362 Pulse/Gal (4.323 Pulse/Liter)
     6″    6.307 Pulse/Gal (1.666 Pulse/Liter)
     8″    3.344 Pulse/Gal (0.883 Pulse/Liter)
     10″  2.150 Pulse/Gal (0.568 Pulse/Liter)
Empty Pipe Detection: Hardware/software, conductivity-based
Environmental: NEMA 4X standard, (IP68/NEMA 6P Option)
Dimensions/Weight:

  • NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation.
    **NOTE: IP68/NEMA 6P Option housing height is 1.1 inchs (28 mm) higher than the standard housing. IP68/NEMA 6P Option housing shipping weight is 3 lbs (1.4 kg) more than the standard housing.

Electromagnetic Flow Meters Options

WMX101-400 4 inch Electromagnetic Flow Meter (PN# BS1040)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

WMX101-600 6 Inch Electromagnetic Flow Meter (PN# BS1060)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

WMX101-800 8 Inch Electromagnetic Flow Meter (PN# BS1080)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

WMX101-1000 10 Inch Electromagnetic Flow Meter (PN# BS1100)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

BATTERY OPERATED ELECTROMAGNETIC FLOW METERS

WMX104-400 4 Inch Electromagnetic Flow Meter, Battery (PN# BS4040)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

WMX104-600 6 Inch Electromagnetic Flow Meter, Battery (PN# BS4060)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

WMX104-800 8 Inch Electromagnetic Flow Meter, Battery (PN# BS4080)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

WMX104-1000 10 Inch Electromagnetic Flow Meter, Battery (PN# BS4100)
NOTE: The Electromagnetic Flow Meters listed above are in units of US gallons and cannot be changed in the field.  Other display units such as MGD, CFM and Liters/minute are available.  Please specify rate and totalizer display units when you order.

ELECTROMAGNETIC FLOW METER ACCESSORIES

FT420W Pulse to 4-20mA Output and Display (PN# BM0210)
Wall mounted, 12-24VDC power required.  Requires DC30 cable for use with WMX104.

AO55W Blind 4-20ma Converter (PN# BM0260)
Wall mounted pulse to 4-20ma converter with no display.  Requires DC30 cable for use with WMX104.

DC30 Field installation cable for WMX104 (PN# BS6020)
External Power/Output Cable, 6m (20 ft).

RELATED PRODUCTS

WMP101 1, 2, or 3 inch Electromagnetic Flowmeter

EX80 Series Fixed Depth Insertion Electromagnetic Flowmeter
Stainless Steel or PVC, for 1 to 8 inch size.

EX100/200 Series Adjustable Depth Electromagnetic Flowmeter
Stainless Steel and Brass Insertion Electromagnetic Flow Sensor, for 3 to 48 inch pipe diameter.

FM500 Ultrasonic Flow Meter
Transit time/Doppler flowmeter with datalogger & 10 FT cable.