TX80 TURBINE INSERTION FLOW METERS
Fixed depth insertion turbine flowmeters

FEATURES:
- High-quality ruby bearings for excellent low-flow performance and long life
- One easily-replaced moving part
- Pickup exerts no magnetic drag on the rotor
- Square-wave frequency output can connect directly to PLC’s or counter controls
- Indicator or transmitter can be mounted on the flowmeter or remote
- Fittings are available in a wide variety of materials and sizes
Turbine Insertion Flow Meter Product Description
The TX80 Series, Turbine Insertion Flow Meters, are turbine-type insertion flow meters designed for use in pipe sizes 1-1/2 to 8 inches. High-quality jewel bearings and nickel-bound tungsten carbide shaft are used for maximum life and extreme low friction. Turbine Insertion Flow Meter bodies are machined from solid rod for maximum precision. Lowflow performance is superior for Insertion Turbine Flowmeters. The rotation of the rotor is detected by a non-drag Hall-effect sensor. The Insertion Turbine Flowmeter’s output is a pulse-type square wave, which can be sent long distances (up to 2,000 feet (650 m)) without a transmitter. This signal can be connected directly to PLC’s, counters, and computer cards.
TX80 Turbine Insertion Flow Meters are ideal for chemical proportioning applications. For rate and total display, as well as pump pacing, the FT415 or FT420 flow indicator can be mounted directly on the TX80 Series Insertion Turbine Flowmeter. For a 4-20mA analog output only, the AO55, blind 4-20mA converter, can be mounted directly onto the meter.
The TX80 Series Turbine Insertion Flow Meters require special fittings, since they are not depth-adjustable, installation in the fitting ensures correct depth placement in the pipe. Fittings are available in PVC, brass, and stainless steel. Insertion Turbine Flowmeters are available in brass, 316 stainless steel, and polypropylene.
The electromagnetic flow sensors male adapters mate with standard 1-1/2 inch (101/201) or 2 inch (115/215) FNPT threaded fittings such as saddles and weldolets. The EX115 and 215 electromagnetic flow sensors include an isolation valve, allowing hot-tap installation, or installation and removal under pressure; a bronze ball valve is standard, with a 316 stainless steel valve option if needed.
Turbine Insertion Flow Meter Specifications
Flow Range: 0.5 – 30 ft/sec (0.15 – 9.14 m/sec)
Accuracy: +2.5% of full scale
Signal: Current sinking pulse, 20 mA max, 30 Vdc max
Rotor Pickup: GMR (Giant Magnetoresistive Sensor)
Maximum Pipe Pressure:
PVC: 175 psi (12 bar) @ 75° F (23.9° C)
Brass, SS: 200 psi (14 bar)
Maximum Temperature:
PVC: 130° F (55° C) at 0 psi
Brass, SS: 200° F (93° C)
Nominal K-factor: 11 Hz/F/s (3.6Hz/M/s)
Power: 6 – 30 Vdc @ 8 mA
Materials:
Sensor Body: PVC, Brass or 316 SS
Rotor: PVFD
Shaft: Carbide
Bearings: Ruby jewel
O-Ring: EPDM
Cable: #22 AWG 3-con 18 ft (6m)
Maximum Cable Run: 2,000 ft (650m)
Dimensions: 1-1/2 inch dia. x 4 inches long(3.8 cm dia. x 10 cm long) Weight: ~2lbs (907g)
Turbine Insertion Flow Meter Options
TX81P Fixed Depth Insertion Turbine Flowmeters (PN# BN0001)
PVC Insertion Turbine Flowmeters, for 1-1/2 to 3 inch pipe diameter.
TX81B Fixed Depth Turbine Insertion Flow Meter (PN# BN0050)
Brass Turbine Insertion Flow Meter, for 1-1/2 to 3 inch pipe diameter.
TX81S Fixed Depth Turbine Insertion Flow Meter (PN# BN0100)
316 Stainless Steel Turbine Insertion Flow Meter, for 1-1/2 to 3 inch pipe diameter.
TX82P Fixed Depth Insertion Turbine Flowmeters (PN# BN0201)
PVC Insertion Turbine Flowmeters, for 4 to 8 inch pipe diameter.
TX82B Fixed Depth Insertion Turbine Flowmeters (PN# BN0250)
Brass Insertion Turbine Flowmeters, for 4 to 8 inch pipe diameter.
TX82S Fixed Depth Insertion Turbine Flowmeters (PN# BN0300)
316 Stainless Steel Insertion Turbine Flowmeters, for 4 to 8 inch pipe diameter.
TURBINE INSERTION FLOW METER SPECIAL FITTINGS
Fittings for TX81 Turbine Insertion Flow Meters:
Required for installation
TF81T-P-150 PVC Tee Fitting (Male stub ends), 1-1/2 Inch Diameter (PN# BN0005)
TF81T-P-200 PVC Tee Fitting (Male stub ends), 2 Inch Diameter (PN# BN0010)
MF82S-P-300-16 PVC Saddle Fitting, 3 Inch Diameter (PN# BN0020)
Installed on 16 inch long pipe stub.
PVC saddles are supplied with Buna-N O-rings only. For chemical service, the O-ring must be removed and the saddle glued on to the pipe with PVC cement.
TF81T-S-150 304 Stainless Steel Tee Fitting, 1-1/2 Inch Diameter (PN# BN0105)
Female thread.
TF81T-S-200 304 Stainless Steel Tee Fitting, 2 Inch Diameter (PN# BN0110)
Female thread.
MF82S-B-300 Bronze Saddle Fitting, 3 Inch Diameter (PN# BN0115)
Fittings for TX82 Insertion Turbine Flow Meters:
Required for installation
MF82S-P-400 PVC Saddle Fitting, 4 Inch Diameter (PN# BN0205)
MF82S-P-600 PVC Saddle Fitting, 6 Inch Diameter (PN# BN0210)
MF82S-P-800 PVC Saddle Fitting, 8 Inch Diameter (PN# BN0215)
PVC saddles are supplied with Buna-N O-rings only. For chemical service, the O-ring must be removed and the saddle glued on to the pipe with PVC cement.
MF82S-B-400 Bronze Saddle Fitting, 4 Inch Diameter (PN# BN0305)
MF82S-F-600 Ductile Iron Saddle Fitting, 6 Inch Diameter (PN# BN0310)
MF82S-F-800 Ductile Iron Saddle Fitting, 8 Inch Diameter (PN# BN0315)
MF82W-S-400 316 Stainless Steel Weld Fitting, 4 Inch Diameter (PN# BN0320)
MF82W-S-600 316 Stainless Steel Weld Fitting, 6 Inch Diameter (PN# BN0325)
MF82W-S-800 316 Stainless Steel Weld Fitting, 8 Inch Diameter (PN# BN0330)
TURBINE INSERTION FLOW METERS ACCESSORIES
FT415M/FT415W Battery Powered Pulse Output and Display (PN# BN0400/BN0410)
Includes 3V replaceable Lithium. Specify meter (PN# BN0400) or wall (PN# BN0410) mounted. Note: Meter mounted displays include 18 feet of cable.

FT420M/FT420W Pulse & 4-20mA Output Display (PN# BM0200/BM0210)
Requires 12-24VDC power. Specify meter (PN# BM0200) or wall (PN# BM0210) mounted. Note: Meter mounted displays include 18 feet of cable.
AO55M/AO55W Blind 4-20ma Converter (PN# BM0250/BM0260)
Requires 24-36VDC power. Specify meter (PN# BM0250) or wall (PN# BM0260) mounted. Note: Meter mounted displays/converters include 18 feet of cable.

RELATED PRODUCTS
EX80 Series Fixed Depth Insertion Electromagnetic Flowmeter
Stainless Steel or PVC, for 1 to 8 inch size.

TX100/200 Series Adjustable Turbine Insertion Flow Sensors
Stainless Steel and Brass Adjustable Turbine Insertion Flow Sensors, for 3 to 48 inch pipe diameter.

EX100/200 Series Adjustable Depth Electromagnetic Flowmeter
Stainless Steel and Brass Insertion Electromagnetic Flow Sensor, for 3 to 48 inch pipe diameter.
SPX Inline Low Flow Meter
Chemical resistant low flow meters for small diameter pipes
WMP101 Plastic Flanged Electromagnetic Flow Meter
The WMP101 flanged electromagnetic flow meters have no rotor to stop turning or bearings to wear out and are virtually maintenance-free, especially in applications where debris or sand would foul most industrial mechanical flowmeters.
WMX101 Magnetic Flow Meter
The WMX101-Series flanged magnetic flow meters have no rotor to stop turning or bearings to wear out and are virtually maintenance-free, especially in applications where debris or sand would foul most industrial mechanical flowmeters.
FM500 Ultrasonic Flow Meter
Transit time/Doppler flowmeter with datalogger & 10 FT cable.