Range of deployment options: 0.72-in (1.83-cm) diameter titanium housing is suitable for harsh environments. The TROLL® Shield Antifouling System extends instrument deployments at high-fouling sites.
Durable design: Titanium
Extended battery life: 5 years or 200,000 readings (1 reading = time and date plus all available parameters polled or logged from the device)
Supported parameters: Actual conductivity, specific conductivity, salinity, total dissolved solids, resistivity, density
Accurate readings
Conductivity sensor: < 80,000 µS/cm ±0.5% of reading + 1 µS/cm; > 80,000 µS/cm ±1.0% of reading
Temperature sensor: ±0.1° C
Pressure sensor: ±0.05% full scale at 15° C
SCADA and telemetry ready: Uses open communication protocols, including Modbus/RS485, SDI-12, and 4-20 mA
Versatile power options: Uses external battery pack or line power
Aqua TROLL 200 Data Logger
The Aqua TROLL® 200 CTD Logger measures and records conductivity, temperature, and water level/pressure.
Conductivity measurements can be used to characterize water quality changes relative to a baseline or to estimate the concentration of contaminants. Plus, you get the highest levels of accuracy when monitoring water level in saline environments.
Rugged Design
- Titanium housing safeguards against corrosion.
- Sealed unit withstands pressures up to 500 psi.
Extended Deployments
- Typical battery life is 5 years or 200,000 readings. External batteries, solar power, or external 8-36 VDC options are also available.
- TROLL® Shield Antifouling System reduces biofouling and increases deployment times.
Accurate Results
- Dynamic density compensation delivers superior water level accuracy in environments where salinity values vary due to mixing, rainfall, or tides.
- Instruments are factory-calibrated and validated with NIST®-traceable standards.
Flexible Communications
Simplified Setup and Data Management
- Win-Situ® Software simplifies programming, data retrieval, and data analysis.
- Standard logging modes include linear, linear average, and event testing1 with logging rates2as fast as 1/sec.
Applications
- Aquifer storage and recovery
- Discharge monitoring
- Estuary and wetland studies
- Mine water management
- Recovery water monitoring at hydraulic fracturing sites
- Remediation projects
- Saltwater intrusion monitoring
- Storm surge analysis
- Tracer studies