WQ900 LAMOTTE WATER POLLUTION TEST KIT
Constituent testing kit for water quality
 
Water Pollution testing kit FEATURES:
 
  • Rugged carrying case
  • Eleven key water quality tests
  • Three water pollution handbooks
 
Product Description

An excellent tool for examining water quality in suspected or known polluted aquatic environments.  A rugged field carrying case contains individual test modules for eleven key water quality test factors, data sheets, and valuable handbooks.  Each individual test module includes complete instructions and all the necessary apparatus and reagents to perform 50 tests.  Three handbooks include A Study of Water Quality, Our Environment Battles Pollution, and Investigating Water Problems.

Specifications

Titration Tests

Test parameter Test method Test range # of reagents
Dissolved Oxygen Modified Winkler method 0.2 to 10.0 ppm (0.2 ppm interval) 5
Hardness, determines calcium, magnesium, and total hardness Uses E.D.T.A. reagent system 0 to 200 ppm 5
Carbon Dioxide Results given as free carbon dioxide 0 to 50 ppm 2
Alkalinity Reads Phenolphthalein (P) and Total (T) Alkalinity, in terms of CaCO3 0.0 to 200 ppm 3
Chlorides, includes salinity test procedure Uses potassium chromate-silver nitrate reaction 0 to 200 ppm 2

Colorimetric Tests

Test parameter Test method Test range # of reagents
pH, wide range indicator Octet comparator with bi-color reader 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, 9.0, 10.0 -
Nitrate-Nitrogen Quartet comparator method, uses the modified A.P.H.A. reagent system 0.2 ppm to 1.0 ppm (0.2 ppm, 0.4 ppm, 0.6 ppm, 1.0 ppm) 4
Phosphate Quartet comparator method, uses the absorbic acid method to produce a series of blue colors 0.2 ppm to 1.0 ppm (values 0.2, 0.4, 0.6, 1.0 ppm) 4
Silica Octet comparator method, uses a modified A.P.H.A. reagent system 0.5 ppm to 10.0 ppm (values 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, 8.0, 10.0 ppm) 4
Ammonia-Nitrogen Octet comparator procedure for ammonia nitrogen by the Nessler method 1.0 ppm to 8.0 ppm (values 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0, 8.0 ppm) 2
Sulfide Octet comparator method, uses the Pomeroy reagent system 0.2 ppm to 20.0 ppm (values 0.2, 0.5, 1.0, 2.0, 5.0, 10.0, 15.0, 20.0 ppm) 3

Water Pollution Test Kit Options

WQ900 Water Pollution Test Kit
Price includes Hazardous Material Shipping Fee
   
WQ901 Reagent Refill    
RELATED PRODUCTS
Individual Water Quality Parameter Test Strips    
4053 Arsenic Testing Kit    
SP200 Variable Speed Portable Peristaltic Sampling Pump
For getting water samples from lakes, rivers, and streams.
   
WS700 Discrete/Composite Sampler
For permanent automated water sampling.
   
Water Quality Sensors
 

  Back to GlobalWater Main Page    |    Back to Testech Home Page    |    M2M Remote Monitoring